EMC Reference Signal Generation – Broadband Comb Generator: CDD-4

The CDD-4 is a broadband comb generator designed to provide stable and repeatable reference signals for electromagnetic compatibility (EMC) testing. It generates a spectrum of harmonics across a wide frequency range, making it ideal for validating test setups, verifying measurement systems, and performing site attenuation checks in both conducted and radiated environments.
Out-of-Stock

EMI Receiver – Full/Pre-Compliance Options: 9010X/XP

The 9010X/XP series from Narda is a line of advanced EMI receivers designed for both full and pre-compliance testing. Covering frequency ranges from 10 Hz up to 6 GHz, these receivers are ideal for small and medium-sized laboratories seeking a cost-effective yet standards-compliant solution. The system is scalable and can be upgraded to full CISPR 16-1-1 compliance with external modules.
Out-of-Stock

EMI Receiver – FFT Analysis & CISPR Compliance: 9010F

The 9010F is a high-performance EMI receiver designed for precise electromagnetic interference (EMI) measurements in the 10 Hz to 30 MHz range. With advanced analog-to-digital conversion and real-time FFT analysis, it ensures full compliance with CISPR 16-1-1 standards. The system is ideal for identifying disturbance sources quickly and reliably in both commercial and military EMC testing environments.
Out-of-Stock

Frequency Extension – External EMI Receiver Units: 9030 / 9060 / 9180

The 9030, 9060, and 9180 are external frequency extension units designed to expand the measurement range of Narda’s 9010 and 9010F EMI receivers. These compact, battery-powered modules enable full compliance testing up to 18 GHz, making them ideal for both commercial and military EMC applications. Each model covers a specific frequency band and integrates seamlessly with the 9010 series.
Out-of-Stock

EMI Receiver – 10 Hz to 30 MHz: Model 9010F – Narda STS

The Narda STS 9010F is a high-precision FFT EMI receiver designed for full compliance with CISPR 16-1-1 standards. It combines advanced analog-to-digital conversion with real-time FFT spectrum analysis, enabling accurate and efficient electromagnetic interference (EMI) measurements. The 9010F is ideal for both commercial and military EMC applications and can be expanded up to 18 GHz with external modules.
Out-of-Stock

EMI/EMC Receiver – full/pre-compliance options: 9010XXP

The Narda 9010XXP series is a family of EMI/EMC receivers designed for full and pre-compliance testing across a wide frequency range from 10 Hz to 6 GHz. These receivers are ideal for small and medium-sized laboratories seeking a cost-effective solution that meets CISPR 16-1-1 standards, with the flexibility to upgrade to full compliance for radiated measurements.
Out-of-Stock

EMI Receiver – 9 kHz to 30 MHz / 3 GHz options: ER8000

The ER8000 is a compact and powerful FFT EMI receiver designed for fast and accurate conducted and radiated emission measurements. It complies with CISPR 16-1-1, MIL-STD-461, ANSI C63.2, and FCC standards, and is suitable for both design validation and certification testing. Its small footprint and intuitive interface make it ideal for use in R&D labs and EMC test environments.
Out-of-Stock

FFT EMI Receiver – 10 Hz to 30 MHz / 3 GHz options: ER9000

The ER9000 is a next-generation FFT EMI receiver designed for high-speed, full-compliance electromagnetic emission measurements. With a frequency range from 10 Hz to 3 GHz (depending on the model), it combines portability, precision, and modularity. Its intuitive color touchscreen and robust construction make it ideal for both laboratory and field use.

For over 50 years, PMM (since 2007 Narda Safety Test Solutions S.r.l.) has been producing innovative and cost-effective measurement receivers and accessories for standard-compliant CISPR and development-related EMC measurement tasks. The new, digital 7000 and 9000 series cover an extremely wide range of applications and at surprisingly affordable prices, starting at €6,000! The advantage of the concept is that it can be upgraded, so that you can, for example, start with conducted tests and later add radiated measurements, all in full compliance with standards! However, “mixed forms” are also possible if the relatively simple conducted measurement is to be carried out in accordance with the standards and the more complex, radiated measurement is only to be carried out during development. A fast FFT option is available, as is a “waterfall analysis” in the time domain. For antenna measurements, the battery-operated expansion module (>30MHz) can be mounted directly on the antenna connection. The signal is transmitted via a fiber-optic connection, which transmits the digitized HF signal to the basic device without loss and interference.

Product Overview:

PMM 9010F:http://www.narda-sts.it/eng/products/receivers/9010f/
10Hz-30MHz; fast FFT frequency spectrum analysis;Full-compliant scan in just 25s instead of 45 minutes
(9kHz-30MHz; RBW 200 Hz / 9 kHz; QP, C-Avg; Hold time 1s)

PMM 9030-9060- 9180:https://www.narda-sts.it/eng/products/receivers/9030-2/
External expansion modules for Model 9010F 30 MHz – 3, 6 and 18 GHz, full-compliant

PMM 9010/03P:
Compliant with standards up to 30MHz, CISPR band A&B; precompliant for CISPR band C, up to 300MHz for CDN and absorption clamp measurement according to EN55015
PMM 9010/30P:
Compliant with standards up to 30MHz, CISPR band A&B; precompliant up to 3GHz
PMM 9010/60P:
Compliant with standards up to 30MHz, CISPR band A&B; precompliant up to 6GHz
http://www.narda-sts.it/eng/products/receivers/xxp/

PMM ER8000:https://www.narda-sts.it/eng/er8000-emi-receiver-with-built-in-lisn/
FFT EMI measuring receiver 9 kHz – 3 GHz, with built-in network simulation 16AUltra-compact, flexible and user-friendly, the ER8000 is a high-performance, fully CISPR 16-1-1 compliant EMI receiver perfect for all conducted and radiated measurements from 9 kHz to 3 GHz

PMM ER9000:https://www.narda-sts.it/eng/products/receivers/er9000/
FFT EMI measurement receiver 10Hz – 3GHz
The latest member of the PMM receiver family adds a practical and intuitive color touch panel display on a robust, compact and highly portable housing, making it an ideal tool for use in both EMC certification laboratories and "in the field" power, also thanks to the Li-ion battery.The very fast scanning time, in full compliance with the CISPR 16-1-1 standard, is guaranteed by optimized FFT technology and without compromising on accuracy

PMM CDD-4 Sethttp://www.narda-sts.it/eng/products/receivers/ca0010/
for continuous and crackling interference according to CISPR 16-1-1 consisting of PMM 9010F measuring receiver and CA0010 clicking analyzer

Software (included)http://www.narda-sts.it/eng/support/software/
The“PMM Emission Suite” software (PES)is the intuitive user interface for controlling the measuring receivers, evaluating and documenting the measurement results. However, the 9010 series also allows easy operation via the keyboard on the front panel.In addition to the measuring receivers, a large selection of accessories is available: antennas, artificial mains network (LISN), click analyzers, and much more.