The 9010/XXP series from Narda Safety Test Solutions / PMM consists of digital EMI receivers designed for full-compliance and pre-compliance electromagnetic emission measurements. The receivers provide CISPR 16-1-1 full compliance in Bands A and B up to 30 MHz, combined with extended pre-compliance capabilities up to 300 MHz, 3 GHz or 6 GHz, depending on the selected configuration.
Featuring advanced digital signal processing, integrated RF preselection and a modular architecture, these instruments support conducted and radiated emission measurements in EMC laboratories, product development and industrial testing environments.
The series also supports future upgrades to higher-frequency full-compliance measurements through external receiver units connected via a high-speed fiber-optic interface.
Advantages
- Full-compliance EMI measurements according to CISPR 16-1-1 in Bands A and B
- Pre-compliance measurements above 30 MHz up to 6 GHz
- Three frequency configurations for different EMC measurement requirements
- Modular expansion capabilities for full-compliance measurements up to 18 GHz
- Digital signal processing with direct A/D conversion up to 30 MHz
- Integrated RF preselection for reliable interference measurements
- Simultaneous detectors for efficient emission analysis
- Smart Detector functionality for reduced measurement time
- Compact and rugged design for laboratory and on-site measurements
- Optional Li-Ion battery for portable operation
- PMM Emission Suite (PES) software for measurement control and analysis
- Optional click analysis, RMS-Average detector and MIL-STD measurement bandwidths
Key Features
- Available frequency configurations:
- 9010/03P: 10 Hz to 300 MHz
- 9010/30P: 10 Hz to 3 GHz
- 9010/60P: 10 Hz to 6 GHz
- Full compliance: CISPR 16-1-1, Bands A and B (9 kHz to 30 MHz)
- Pre-compliance: above 30 MHz, depending on the model and measurement conditions
- Direct analog-to-digital conversion up to 30 MHz
- Integrated RF preselector and switchable 20 dB preamplifier up to 30 MHz
- Integrated switchable pulse limiter in the low-frequency receiver section
- Measurement detectors: Peak, Quasi-Peak, Average and RMS, available simultaneously
- Optional RMS-Average detector
- CISPR measurement bandwidths: 200 Hz and 9 kHz up to 30 MHz; 120 kHz above 30 MHz
- Optional MIL-STD-461 measurement bandwidths
- RF input impedance: 50 Ohm
- BNC input up to 30 MHz and N connector for higher frequencies
- Maximum RF input level without damage: 137 dBµV (1 W)
- Integrated tracking generator for additional RF measurements
- Optional click measurement functionality
- Interfaces: USB 2.0, RS-232, fiber-optic interface and User Port
- External LISN control via User Port
- Expansion with external full-compliance receiver units 9030, 9060 and 9180
- Power supply: 10 to 15 V DC; optional Li-Ion battery
- Dimensions: 235 × 105 × 335 mm
- Weight: approximately 4.1 kg
Typical Applications
- Full-compliance conducted emission measurements using suitable external LISNs
- Radiated EMC pre-compliance testing up to 300 MHz, 3 GHz or 6 GHz
- EMC measurements in testing and development laboratories
- EMC pre-compliance testing during electronic product development
- Electromagnetic interference diagnostics and troubleshooting
- EMC testing of industrial and commercial electronic equipment
- Measurements in anechoic chambers and open-area test sites
- Quality assurance and EMC validation in production environments
- RF filter characterization using the integrated tracking generator
- Higher-frequency full-compliance emission measurements with suitable external receiver units
Additional Information
The 9010/XXP series is available in three frequency configurations. The 9010/03P covers frequencies up to 300 MHz, the 9010/30P extends the measurement range to 3 GHz and the 9010/60P supports measurements up to 6 GHz.
All three models provide CISPR 16-1-1 full compliance in Bands A and B. Above 30 MHz, model- and signal-dependent limitations apply, particularly with respect to the pulse repetition frequency of broadband disturbances.
For full-compliance measurements at higher frequencies, the instruments can be expanded using external receiver modules: 9030 up to 3 GHz, 9060 up to 6 GHz and 9180 up to 18 GHz. The modules are connected through a high-speed fiber-optic interface.
Additional measurement capabilities are available through the optional 9010/CLICK, 9010/RAV and 9010/MIL extensions. Conducted emission measurements require an appropriate external LISN.
EMCO Elektronik provides technical consultation and support for selecting the appropriate receiver configuration, designing expandable EMC measurement systems and integrating the 9010/XXP series into existing test environments.
| Feature | 9010/03P | 9010/30P | 9010/60P |
|---|---|---|---|
| Frequency range | 10 Hz – 300 MHz | 10 Hz – 3 GHz | 10 Hz – 6 GHz |
| Full CISPR 16-1-1 compliance | 9 kHz – 30 MHz | 9 kHz – 30 MHz | 9 kHz – 30 MHz |
| Extended frequency range above 30 MHz | Up to 300 MHz | Up to 3 GHz | Up to 6 GHz |
| Direct A/D conversion up to 30 MHz | Yes | Yes | Yes |
| Smart Detector | Yes | Yes | Yes |
| PMM Emission Suite | Yes | Yes | Yes |
| Click measurement function | Optional | Optional | Optional |
| External full-compliance modules | Supported | Supported | Supported |
| Typical application | Conducted testing and pre-compliance up to 300 MHz | Conducted testing and pre-compliance up to 3 GHz | Conducted testing and pre-compliance up to 6 GHz |